Journal of Fire Sciences

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Google Scholar
Right arrow Articles by Chow, W.K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Fire Sciences, Vol. 26, No. 4, 311-329 (2008)
DOI: 10.1177/0734904108089567

Necessity of Testing Combustibles under Well-developed Fires

W.K. Chow

Research Center for Fire Engineering, Area of Strength: Fire Safety Engineering The Hong Kong Polytechnic University, Hong Kong, China, bewkchow{at}polyu.edu.hk

Flashover might occur rapidly as a consequence of an arson fire in a small enclosure such as a retail shop in the Far East. Testing the products, especially those made of new synthetic materials modified with additives, in well-developed fires after flashover is necessary. This refers to both full-scale burning tests on the product and bench-scale tests under higher radiative heat fluxes. Starting a room fire test with a small fire source as in the room calorimeter and stopping it upon reaching flashover would only give the `flashover propensity.' This is good enough only for designing fire safety provisions under accidental fires. Information on the heat release rate, burning duration, smoke generation rate and the toxicity of real-scale fires cannot be determined. In this article, the necessity of testing combustibles under post-flashover conditions in fire hazard assessment is pointed out. Several arrangements in retail shops are described to support the argument. Equations in the literature on estimating the maximum heat release rates for well-developed fires in those small spaces are assessed.

Key Words: well-developed fire burning • post-flashover • big fire • high combustible contents.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?